It is imposed with a 10mA current such that when the metal is excited electrically, characteristic spectral line/lines are emitted and passed directionally through a glass UV/VIS window of the lamp. flame atomic absorption spectroscopy (faas) nebulisers play an important role in sensitivity most critical part of instrument. If you compare the block diagram of an AAS vs a typical visible spectrometer, you'll note that the wavelength selector is typically placed after the sample compartment for AAS to address these concerns about scattered light however the issue is not that significant in visible spectroscopy so the wavelength selector can be placed before the sample holder. The Hollow cathode Lamp is made with an element (metal) as the cathode encased in a bulb with a low pressure inert gas. Lajunen.Ī wavelength selector is needed in order to ensure that only one of the emission lines is being used for the analysis.Īdditionally, light can be scattered in the flame, which can introduce errors in the analysis if not eliminated. The background attenuation is then subtracted from the measured analyte absorbance to obtain the analyte absorbance. of a specific wavelength from a hollow cathode lamp (HCL), passing through the flame.

The total or gross absorbance is measured at the wavelength of the resonance line emitted by the hollow cathode lamp (HCL). Direct Aspiration or Flame Atomic Absorption Spectrometry (FAAS). Here, for example, is the emission from a nickel HCL, taken from Spectrochemical Analysis by Atomic Absorption and Emission by L. In all background correction systems two measurements are made. 4.3A: CHN Analysis by Combustion 4.4: Computational Analysis - Thermogravimetry (TG) Guystav Kirchoff and Robert Bunsen first used atomic absorption spectroscopyalong with atomic emissionin 18 as a means for identify atoms in flames and hot gases. The emission spectrum from HCLs have multiple lines. The first point to consider is what the source really looks like.

Atomic absorption spectroscopy (AAS) uses a hollow cathode lamp (HCL) as a source, and HCLs are line sources therefore, if a line source is being used, why would an instrument need to be made more complex by adding a wavelength selector? The Hollow Cathode Lamp The hollow cathode lamp (HCL) uses a cathode made of the element of interest with a low internal pressure of an inert gas. This question has lingered on the site for a long time, which is a shame because it is a good question to ask. The hollow cathode lamp (HCL) achieves this by using a high-energy discharge to stimulate emission from the element of interest.